The National 5200QL is a battery-powered ride-on floor scraper with a slide-out battery pack that loads from the rear, so a charged pack can be swapped in on jobs that need continuous operation. National lists it for commercial surface removal and preparation and says it is quiet and compact enough for residential jobs. The 2026 National catalog lists it as a special-order machine.
Specifications
Figures from National's product page and operating manual. Where the two disagree, both are shown with the manual first.
| Spec | Value |
|---|---|
| Power | Battery, 48V; 4 HP (2.98 kW) (manual) |
| Charger | 48 V battery charger, part 5212 (manual parts list) |
| Input voltage | 120V/60 Hz domestic; 100V international, 5200QL-28XXXX (manual); 115V 60 Hz / 100V 50/60 Hz (product page) |
| Dimensions (W x L x H) | 24.75" x 57" x 46.5" (63 x 145 x 119 cm) (product page) |
| Weight | Net 1,945 lb (882 kg) (manual); 1,760 lb (798.3 kg) (product page) |
| Machine only | Unweighted 1,500 lb (680 kg) (manual); 1,315 lb (596.5 kg) (product page) |
| Removable weight | 370 lb (167.8 kg) front; 75 lb (34 kg) rear |
| Speed | Up to 120 ft/min (36.6 m/min) |
| Hydraulic tank | 6 gallons (22.7 L) (manual) |
Maintenance schedule
From National's 5200QL operating and service manual (402228 Rev E), page 17.
| Interval | What to do |
|---|---|
| Daily | Inspect extension cord for damage; check wheels, caster and wheel motors for build-up and clean; inspect all safety devices (e-stop, backup beeper, seat switch); inspect hoses and fittings for leaks; blow out the fan cover on the bottom of the motor after each job |
| After first 100 hrs, then every 200 hrs | Check hydraulic oil level; replace spin-on hydraulic oil filter |
| After first 500 hrs, then every 1,000 hrs | Change hydraulic fluid |
| Every 1,000 hrs | Grease front caster wheel |
Fluids and lubricants
What National specifies for this machine.
- Hydraulic oil: Texaco Rando 46 or a compatible ISO or AW #46 fluid from a brand-name manufacturer. Tank holds 6 gallons (22.7 L) total; plan on 5.5 gallons (20.8 L) at an oil change because some oil stays in the system.
Videos from National
National has no 5200QL-specific videos posted. These general battery ride-on videos apply to it.
- Battery Ride On Scrapers Start-Up
- Ride-On Scraper Battery Replacement
- Test the Battery Load on Your Rider
Sources
Everything on this page comes from these National Flooring Equipment pages and documents.